Visualiser le Raid

Il s’agit d’un Raid1 matériel Smart Array P410 sur serveur HP ProLiant DL160 G6
OS = Debian Stretch

Installer l’utilitaire :
# apt-get install cciss-vol-status

Regarder l’état du Raid :
# cciss_vol_status -V /dev/sda

Controller: Smart Array P410
Board ID: 0x3243103c
Logical drives: 1
Running firmware: 5.70
ROM firmware: 5.70
/dev/sda: (Smart Array P410) RAID 1 Volume 0 status: OK. At least one spare drive designated. At least one spare drive remains available.
Physical drives: 3
connector 2I box 1 bay 1 ATA GB0500EAFYL WCASYC753396 HPG4 OK
connector 2I box 1 bay 2 ATA GB0500EAFYL WCASYC753928 HPG4 OK
connector 2I box 1 bay 3 ATA MB0500EBZQA Z1M0DRXV HPG2 OK

/dev/sda(Smart Array P410:0): Non-Volatile Cache status:
Cache configured: Yes
Read cache memory: 100 MiB
Write cache memory: 300 MiB
Write cache enabled: Yes

Leave a Reply